  I. important information

  This information is for those professionals who can select and connect to install the switcher. The use of keymonth TSC series devices must strictly comply with the national standards related to the industry, although some standards are not reflected in this information.

  Ⅱ. application

  Ky-tsc series switch is used to switch capacitor in three-phase system. Compared with other switches, the switch has no inrush current, no contact noise and high switching frequency. These advantages are realized by trigger circuit, thyristor, diode and some auxiliary circuits. The switch is suitable for the occasion of fast load change.

  III. composition unit

  The switch is mainly composed of two-way thyristor, trigger circuit, absorption circuit, heat sink, cooling device and other components. The output circuit judges whether to output control signal (DC12V) before and after voltage zero crossing, so as to make the thyristor turn on or off. The trigger circuit can reliably guarantee the output of control signal, the good heat conduction function of heat sink and the addition of heat sink fan, which greatly improves the heat dissipation effect of the switch. The device has a built-in over temperature protection switch and a temperature switch to control the automatic operation of the fan, thus providing good conditions for safe operation.

  IV. installation instructions

  When installing the module, please pay attention to the IP protection level, temperature level and the maximum installation position. The ambient temperature will directly affect the electrical life of the module equipment. When the capacity of the single cabinet stacked module is too large, it is recommended to install high-power fans to exhaust heat and cool down. The fan ventilation capacity standard is in accordance with the following table.

                                Capacity of single cabinet installed capacitor (kvar)                       Ventilation capacity (m3 / h)

                                                          Less than 50                                                                        Eighty

                                                           50 - 100                                                                 One hundred and sixty

                                                         100 - 200                                                                Three hundred and sixty

                                                         200 - 250                                                                         Six hundred

                                                    More than 250                                                                    Nine hundred

  If necessary, install ventilation cooling in the distribution room. The module equipment shall be installed stably to ensure sufficient space around the cabinet to facilitate maintenance and repair after installation.

  Prompt: the equipment is suitable for vertical installation, and the vertical distance between switching switches shall be kept at least 10cm. If multiple rows of switches are to be installed according to the requirements, the rows shall be staggered with each other to facilitate the ventilation and heat dissipation of the equipment, and a certain horizontal distance shall be kept for the convenience of wiring and heat dissipation.

  V. equipment inspection

  The reactive power compensation module you ordered will leave the factory after passing the inspection of our quality inspection department.

  u  before you are ready to install the device, please confirm the following preparations:

  u  check whether the packing box is in good condition and whether there are heavy damaged parts in the packing after transportation.

  u  check whether the mechanical part and electrical part of the module equipment are obviously damaged.

  u  check whether the rated voltage, current, frequency and other technical parameters on the nameplate of module equipment match with the local power grid parameters.

  Vi. the module (switcher) mainly has the following characteristics:

  u  zero crossing switching, no inrush current, no grid voltage flicker

  u  photoelectric isolation, strong anti-interference ability, fast response speed, (50ms)

  u  no inrush, no impact, will not cause grid voltage flicker.

  u  integration, small size, easy installation.

  u  LED signal light shows switching status.

  u  touch safe connection technology, IP30.

  No noise and mechanical wear during operation, greatly extending service life.

  Compared with the traditional contactor, the device has no inrush current, no impact, no transition process, no mechanical wear, no noise, and can follow the change of system load in real time to switch on and off the capacitor without causing the flicker of system voltage. After a long time of operation, the product has been proved to be stable in performance, safe and reliable in operation.