KYZ Type Fully Isolated Single Phase Intelligent Voltage Regulating Module

  I. overview

  KYZ type fully isolated single-phase intelligent AC voltage regulating module (hereinafter referred to as single-phase voltage regulating module) is an intelligent phase-shifting voltage regulating module which integrates power supply, synchronous transformer and phase-shifting trigger circuit. It has soft start and soft stop function to reduce the impact on load. The module has optoelectronic isolation between the input end and the output end in order to realize the control of weak current to strong current and the control of output load power by the input end. With high input impedance, it can be directly connected with computer and digital programmable circuit through digital-to-analog converter. It is very convenient to realize stepless regulation of output load voltage and power. It is widely used in lighting equipment, temperature control equipment and soft start of AC motor, AC series speed regulation and other power automatic regulation occasions.

  Ⅱ. Performance characteristics

  ○ It can directly interface with the output signals of various control instruments (temperature controllers) and microcomputers at home and abroad.

  ○ It is suitable for resistive load, inductive load, primary side of transformer and other load types.

  ○ It has soft start function, reduces the impact of interference on the power grid, and is more safe and reliable to use.

  ○ Urgent stop function.

  ○ Encapsulated with epoxy resin shell, it is safe, convenient, dust-proof and moisture-proof.

  Ⅲ. Main Technical Indicators and Their Use

  Control signal: 4-20mA DC 0-5V DC 5-0V DC 0-10V 2-10K potentiometer (manual adjustment)

  Voltage regulation range: 0-220 VAC 0-380 VAC 0-440 VAC.

  Phase shift range: 0-178.

  IV. Working methods

  1. Four input modes can be selected:

  ○ 4-20mA input. COM corresponds to the control input negative end.

  ○ 0-10V input. COM corresponds to the control input negative end.

  ○ 0-5V input. COM corresponds to the control input negative end.

  ○ Manual potentiometer input. The + 10VDC voltage output terminal of the intelligent voltage regulating module is the power supply for the manual voltage regulating control potentiometer (which is not used here). The output terminal of the potentiometer is connected to 0-10V port, and the other end corresponds to COM port. The resistance of the potentiometer selected is 4.7-10K.

  ○ Customers may apply to our company for customization when they require input of special control signals such as 0-20mA, 0-10mV, 5-0V etc.

  2. If the voltage added to the load is different, please declare the voltage size of the two, our company can customize for users, but the phase of the two must be the same, and (3) the voltage level of 220 VAC, 380 VAC or 440 VAC, 50HZ. (1) There is no polarity between (2) and (3) between (4). For example, if the rated voltage of a load is 36 VAC (220 V power grid is decompressed by transformer), and the single-phase voltage regulating module of 75A is selected, the module of KYZ-H36D75P can be customized to our company. Among them, the foot is connected to the 36V power grid in series with the load, and the foot is connected to the 220V power grid, such as (Fig. 5):

  3. The single-phase intelligent voltage regulating module has three input power sources: 220 VAC, 380 VAC and 440 VAC. Users should inform our company when selecting the type, so as to avoid burning the voltage regulating module by selecting the wrong voltage level.

  V. Shape Dimensions and Application Circuit Diagrams

  VI. Classification and Naming

  KYZ-H  D  P

                     Maximum nominal

                         Rated operating voltage

                         Enhanced type, normal type without H

                         Model of Intelligent Voltage Module

                         Type Table of Single Phase Voltage Regulating Module

Ⅶ. Type Table of Single Phase Voltage Regulating Module


Enhanced type

15A

   KYZ-H220D15P

Ordinary type

10A

   KYZ-220D10P

25A

   KYZ-H220D25P

15A

   KYZ-220D15P

35A

   KYZ-H220D35P

25A

   KYZ-220D25P

45A

   KYZ-H220D45P

40A

   KYZ-220D40P

60A

   KYZ-H220D60P

Half-waveform

10A

   KYZ-220D10×P

80A

   KYZ-H220D80P

15A

   KYZ-220D15×P

100A

   KYZ-H220D100P

25A

   KYZ-220D25×P

120A

   KYZ-H220D120P

25A

   KYZ-220D25×P

150A

   KYZ-H220D150P

50A

   KYZ-220D50×P

200A

   KYZ-H220D200P

75A

   KYZ-220D75×P

240A

   KYZ-H220D240P

120A

   KYZ-220D120×P


 Note: If applied to 380VAC or 440VAC power grids, 220 in the table should be changed to 380 or 440.


VIII. TABLE OF TECHNOLOGICAL PARAMETERS

  

input parameter

Company

Parameter value

  Synchronous supply voltage

Vac

180-240

280-420

 Control signal voltage range

Vdc

0-5/1-5/0-10/5-0V或4-20mA

  potentiometer

2-10KΩ


 


Output parameters (general type)

Company

Parameter value

Nominal current

Arms

10

15

25

40

Nominal current

Arms

0.1-10

0.1-15

0.1-25

0.1-40

Surge Current 20mSec(Max)

Arms

85

115

230

400

Voltage adjustment range

Vrms

0-220/0-380

Thyristor blocking voltage (220V)

Vpk

≥600

Thyristor blocking voltage (380V)

Vpk

≥1000

frequency range

Hz

47-63

Breakdown voltage rise rate DV / dt (min)

V/usec

100

Breakdown Leakage Current (max)

mArms

﹤8

Phase shift range


0-177°

Insulation Voltage (Input/Output/Baseboard)

Vrms

2000


 

    Parameter out (general type)

    Company

    Parameter value

    Nominal current

    Arms

    15

    25

    35

    45

    60
    80

    Nominal current

    Arms

    0.1-15

    0.1-25

    0.1-35

    0.1-45

    0.1-600.1-80

    Surge Current 20mSec(Max)

    Arms

    200

    300

    400

    $(document).ready(function(){ $(".index_01 .pro_img .thumbnail > img").click(function(){ var index=$(this).index(); //console.log($(this)); console.log(2); $(this).next(".img_po").css("display","block"); //$(".index_01 .in_pro .img_po").eq(index).css("display","block"); }); $(".index_01 .pro_img .thumbnail > .img_po").click(function(){ //var index=$(this).index(); //console.log($(this)); console.log(1); $(this).css("display","none"); //$(".index_01 .in_pro .img_po").eq(index).css("display","block"); }); })